KEYWORDS: Sensors, Weapons of mass destruction, Homeland security, System identification, Polarization, Platinum, Ions, Electric field sensors, Detector arrays, Defect detection
We present the results from testing over 100 5x5x12 mm3 TlBr detectors configured as 3D position-sensitive virtual Frisch-grid (VFG) detectors with platinum contacts. The primary objective was to comprehensively understand factors limiting performance and long-term response variations in these detectors. The incorporation of 3D position sensitivity allowed us to monitor internal changes in charge collection efficiency after applying voltage, and to correlate them with device performance changes. The biased detectors underwent defect distribution alterations due to electric field-enhanced ion migration. Our results are based on an extensive dataset obtained from TlBr crystals produced by Radiation Monitoring Devices (RMD). These measurements were part of our development of a handheld isotope identifier based on an array of position-sensitive TlBr detectors, supported by the Department of Homeland Security, Countering Weapons of Mass Destruction Office. The majority of the detectors exhibited a common trend of performance improvement within 1-2 weeks, stabilization for some period of time, then a slow degradation; however, some detectors deviated from this pattern.
The ComPair gamma-ray telescope is a technology demonstrator for a future gamma-ray telescope called the All-sky Medium Energy Gamma-ray Observatory (AMEGO). The instrument is composed of four subsystems, a double-sided silicon strip detector, a virtual Frisch grid CdZnTe calorimeter, a CsI:Tl based calorimeter, and an anti-coincidence detector (ACD). The CsI calorimeter's goal is to measure the position and energy deposited from high-energy events. To demonstrate the technological readiness, the calorimeter has flown onboard a NASA scientific balloon as part of the GRAPE-ComPair mission and accumulated around 3 hours of float time at an altitude of 40 km. During the flight, the CsI calorimeter observed background radiation, Regener-Pfotzer Maximum, and several gamma-ray activation lines originating from aluminum.
We present the results from testing the performance of CdZnTe (CZT) position-sensitive virtual Frisch-grid (VFG) detectors for gamma-ray imaging. Large-volume CZT detectors with dimensions up to 10x10x30 mm3 recently became available from CZT crystal vendors. Such devices improve detection efficiency and position resolution when integrated into position-sensitive photon counting cameras proposed for nonproliferation, nuclear security, and gamma-ray astronomy. It is important to evaluate the factors affecting the response uniformity and limiting the performance of these detectors. In general, the response non-uniformities could be caused by detector geometries, materials inhomogeneity, and crystal defects. Several techniques have been developed to correct response non-uniformities and improve detector performance. Among them are the high-granularity position-sensitive detectors, which provide the most accurate and robust corrections. Position sensitivity can also be used to reveal response non-uniformities and understand their causes during the detector development or fabrication stages. Here, we describe a technique that we developed for position-sensitive virtual Frisch-grid detectors employing CdZnTe (CZT) and other semiconductors. To illustrate our experimental technique, we measured responses from the selected detectors of different qualities acquired from different vendors and grown by different methods.
TlBr is a promising material for room-temperature semiconductor gamma-ray detectors currently under development by several groups around the world. TlBr has the optimal combination of properties: high atomic number, high density, high mu-tau product, low Fano factor, and lower fabrication cost compared to other materials. The presence of crystal defects and ionic drift-diffusion enchained by the electric field affects the performance of today’s TlBr detectors. As a bias is applied across a detector, a defect distribution inside starts changing due to ion migration. The changes appear to be most pronounced in the first weeks of applying a bias to newly-manufactured crystals during the “conditioning” period. The 3-D position-sensitive detectors provide an opportunity to investigate these processes and their effects on the device performance and on corrections applied to the spectrum. Here, we present results from analyzing response changes in TlBr crystals under applied biases using position-sensitive capacitive Frisch-grid detectors.
This work has been supported by the U.S. Department of Homeland Security, Countering Weapons of Mass Destruction Office, under competitively awarded contract 70RDND18C00000024. This support does not constitute an express or implied endorsement on the part of the Government.
We report on the results from testing CdZnTe (CZT) position-sensitive virtual Frisch-grid (VFG) detectors and a prototype of a 16x16 detector array proposed for a high-energy gamma ray imaging space telescope. Previously, we evaluated the spectroscopic performance of these detectors. Here, we present results from our detector performance studies with an emphasis on position resolution. We employed digital waveform capturing and analog ASIC based approaches to read out the signals from the detectors and evaluate their spectral- and spatial-resolution. The VFG arrays allow for the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors’ response non-uniformities caused by crystal defects and device geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large
The LSST Camera focal plane will be constructed with 21 144-Mpixel modules (“Raft Tower Module”, RTM). An extensive operational test is performed to confirm the integrity of all connections and to verify the basic functionality. Each RTM undergoes at least four connectivity tests. A python script communicates with Java- based control software and performs the test. A final script parses the test data and generates a PDF report. The report includes a summary PASS/FAIL table, several hundred current, voltage and temperature parameters, and images taken with the CCD array at room temperature.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.