KEYWORDS: X-ray optics, X-rays, Rockets, Calibration, Solar processes, Mirrors, Solar radiation models, Point spread functions, Hard x-rays, X-ray imaging
We have been developing X-ray optics for a fourth FOXSI (Focusing Optics X-ray Solar Imager) sounding rocket experiment, FOXSI-4. We fabricated two types of X-ray optics, soft X-ray optics (SXR) and hard X-ray optics (HXR), specified for soft and hard X-ray observations. We conducted X-ray irradiation tests to evaluate X-ray performances such as angular resolution and effective area. For the Flight Model (FM) SXR, the resultant angular resolution in Half Power Diameter (HPD) is 16 ± 2 / 14 ± 2 arcseconds at 2.7 / 4.5 keV for the best images, respectively and no significant energy dependence in HPD is seen. The observed effective area was reproduced within an accuracy of 10% by using our original ray-tracing simulator considering all of the SXR components in the 1.5-16 keV range at the smallest off-axis angle. Subsequently, both FM mirror module assemblies were integrated into a sounding rocket in combination with detectors and the vibration tests were performed for the whole sounding rocket system. Finally, FOXSI-4 was successfully launched on April 17, 2024 (UTC), and the sounding rocket and the data were also recovered successfully.
We have been developing our original space X-ray optics by combining space- and ground-based technologies for a solar sounding rocket experiment, FOXSI-4. We completed two Flight Models (FM), soft and hard X-ray optics. Vibration tolerance is one of the most important launch environmental tolerance and thus we established our experimental setup for the two FMs. The imaging quality was evaluated before and after the vibration tests. As a result, no significant changes were detected. In addition, we checked the effect of shims needed for the angle alignment between the optics and detectors integrated into the sounding rocket. We confirmed that the shims do not affect the angle alignment significantly before and after vibration tests.
We have been developing high-resolution space X-ray optics by using high-precision electroforming technology which has been refined through the development of ground-based X-ray focusing systems. Our optics have been on board the Japan-U.S. joint NASA sounding rocket experiment, the 4th Focusing Optics X-ray Solar Imager (FOXSI-4), which succeeded in the world's first X-ray imaging and spectroscopic observation of solar flares. So far, we have conducted ground calibration tests on these onboard items. We have been building our own ray-tracing simulator in order to model the data and finally construct a response function which is essential for obtaining physical parameters in imaging and spectroscopic analysis accurately. In this paper, we modeled the uncertainty of the reflection angle due to the surface shape error in the axial direction and implemented it in this simulator for the first time. As a result, we succeeded in reproducing the point spread function up to ~50 arcsec assuming a Cauchy distribution and confirmed the consistency between simulations and the data in terms of FWHM and HPD for the on-axis direction. Additionally, we optimized parameters of a Cauchy distribution also for the off-axis data and investigated the dependence of the parameters on the off-axis angles.
The atmospheric characterization of habitable candidates is one of the effective approaches for search for life out of the solar system. However, it is much hard by high planet-star flux contrast, 10-8 - 10-10 . A coronagraphic mask proposed by Itoh & Matsuo (2020) can suppress host stellar light but is imposed by a strict wavelength range limit of 0.3%. A spectroscopic coronagraph that combines the diffraction-limited coronagraph with a spectrograph is expected to achieve enlarges the effective bandwidth. On the other hand, a non-common path error, which is induced by the spectrograph, could limit the achievable contrast. We designed a high-accuracy spectrograph motivated for the spectroscopic coronagraph and measured its wavefront error. The common path error is 9.9 nm RMS, which is mostly caused by the alignment error between the convex grating and spherical mirror of the spectrograph. The achievable contrast of the spectroscopic coronagraph was also estimated from the non-common path error measurement. We found that the contrast of 10-8 could be achieved with a bandwidth of 5%, which is a promising result as the first step.
Wolter mirrors work as imaging optics of X-ray telescopes. We have been developing a Wolter mirror for the FOXSI-4 project in 2023 using a high-precision Ni electroforming process. The figure accuracy of mirrors is one of the main factors determining the spatial resolution in X-ray imaging. In this study, we optimized the electrodeposition conditions from the viewpoint of the uniformity of film thickness. The simulation model was developed to correctly predict the film thickness distribution before fabrication, whose parameters and boundary conditions were determined through electrochemical experiments. The model calculates the distribution of current density on the surface of the cathode by finite element analysis. In this paper, we report the current status of the electroforming process specializing in Wolter mirrors in X-ray telescopes.
For many years, Wolter mirrors have been used as imaging elements in X-ray telescopes. The shape error of Wolter mirrors fabricated by replicating the shape of a mandrel originates from the replication error in electroforming. We have been developing an X-ray focusing mirror for synchrotron radiation X-rays, as well as a high-precision electroforming process. In this paper, we report on the application of the advanced electroforming process to the fabrication of Wolter mirrors for the FOXSI Sun observation project. We also discuss the figuring accuracy of the mandrel.
We had been developing replicated aluminum foil optics for previous missions such as ASCA, Suzaku, and, Hitomi. This sort of X-ray optics can be lighter but the angular resolution is limited to on the order of arcminutes. Thus, to improve the angular resolution with light performances, we have started developing electro formed X-ray optics. Electroforming is a technology that can transfer to a substrate with high accuracy by plating the nano-level structure of a super-precision master and makes it easier to fabricate Wolter type-I shaped two-stage full-shell mirrors.
Electroforming replication is an essential technique for fabricating full-shell, grazing-incidence mirrors for use in space, laboratories, and synchrotron experiments. For X-ray astronomy, a nickel electroforming replication process was developed and is used to produce lightweight and high-resolution X-ray mirrors. In addition, the electroforming process for fabricating X-ray mirrors for use in synchrotron experiments has undergone remarkable development over the past decade. We expect that the use of the ground-based electroforming replication process for the production of optics for Xray astronomy will lead to further improvements in the performance of X-ray telescopes. This paper describes our ongoing development efforts in the nickel-electroforming replication process, including the results of a pilot study.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.