The variability estimates of the electric field potential gradient in an arid region of Southern Siberia are obtained from insitu measurements in the Shol tract (Tyva). The analysis of variations of the electric field, meteorological quantities, aerosol content and solar radiation in the surface layer during a sandstorm was carried out. During this phenomenon, three types of disturbances were noted in the surface electric field.
Estimates are obtained for the variability of atmospheric electrical quantities (electric field potential gradient and concentrations of positive and negative air ions) under electrically undisturbed atmospheric conditions. In-situ measurements were carried out in the mountainous and steppe landscapes of Khakassia and Tyva (Southern Siberia) during the warm period of 2022. A comparative analysis of the results obtained was carried out. The maximum concentration of positive air ions was recorded in the hilly steppe near salt lakes, the maximum concentration of negative air ions was recorded in the central part of the basin, and the maximum electric field potential gradient was recorded in high mountains.
The influence of the passage of mesoscale convective complexes (MCC) on γ-ray background and the meteorological quantities in the surface layer are presented in paper. It is noted, that the surface electric field reacts to the passage of the MCC earlier than other measured quantities. This temporary delay is 1 hour. After the rain ended, the elevated radiation background remained for more than 2 hours.
We present the time series of the total ozone content (TOC) over Tomsk, obtained using three independent spectrophotometers, and carry out their comparative analysis. Comparison of measurements by these instruments shows that they well correlate in terms of the pronounced variations, arising in time behaviors; but the amplitudes of the bursts differ. On the whole, we can note that the TOC values, obtained using IAO instrument, exceed those from two other instruments, TOC values from NASA instrument being the lowest. These smallest TOC values are especially apparent for the summer and fall periods.
In the study, estimates of the variability of the surface electric field in undisturbed atmospheric conditions in Tomsk were obtained. It is noted, that the average and mode of the potential gradient in Tomsk under fair-weather conditions are ~280 and 250 V/m, and it is a typical range is 160–370 V/m. In the warm period of the year, the average and range of the potential gradient are 1.2 and 1.5 times, which less than in the cold period.
The slow variations of electric field potential gradient were investigated during the passage of mesoscale convective complexes (MCC) over the city of Tomsk. Variations of potential gradient during the MCC are characterized by prolonged periods of negative disturbance related with the passage of the base of the cloud system, which has mainly a negative charge, according to 31 cases. The positive disturbance has a shorter duration and is linked to the anvil. Variations of electric field potential gradient under the effect of MCC have an average duration of 2 hours and an amplitude of 12 kV/m.
It is noted that smoke plumes from remote forest fires bring, on the one hand, a significant decrease in the average values of the potential gradient of the electric field in the surface layer and, on the other hand – to a strong increase in their dispersion as compared with the "fair-weather" conditions. It is shown that the electric field decreases with an increase in the optical density of the smoke plume.
The influence of severe frosts in the cold season, accompanied by ice fog creation, on the atmospheric-electric and meteorological quantities in the urban surface atmosphere in Siberia is considered. The assumption that a decrease of electric field potential gradient (∇φ) and an increase of air electrical conductivity (λ±) in the surface atmosphere during severe and prolonged frosts are caused by the changes of the fog particles phase state (liquid to crystalline) and the shape of ice crystals at temperature below –16°C and by the decrease of absolute humidity at temperatures below –35°C was made.
The results of studies of the consistent variability of the parameters of the electrode layer of the atmosphere during the passage of thick convective clouds accompanied by rainfall are presented. For a series of cumulonimbus cloud passes with heavy showers high-frequency (periods of less than 10 min) fluctuations in the structure of precipitation in time and size spectrum were analyzed. A correspondence between the variations of hydrometeors flow, electric field potential gradient (∇φ) and polar conductivities (λ±) has been established.
A multi-position complex consisting of three automatic weather stations TAA-01 carried out pilot measurements of meteorological, actinometric, and atmospheric-electrical quantities at extremely low temperatures. The state of atmospheric surface layer during heavy frosts caused by the invasions of arctic air mass in winter was analyzed.
The ecosystem-atmosphere exchange of methane and carbon dioxide were measured during the summer campaigns 2014 – 2017 in Plotnikovo (N56°51’, E82°51’) on the wetland Flux-NIES automatic chamber complexes. Eleven vegetative groups on the bog’s surface and one lake site were taken in comparison. The objective of these particular measurements was to estimate the growing season carbon fluxes at sedge fen and on hollow-ridges nearby lake at Siberia ecosystems. The carbon balance of these ecosystems deeply relies on the peat wetness. Another objective was the integration of carbon fluxes from aquatic systems into terrestrial ones, in order to quantify and better understand the catchment scale carbon budget.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.