Lightweight, aluminum, freeform prototype mirrors have been designed and fabricated by a Thai led team, with UK support, for intended applications within the Thai Space Consortium (TSC) satellite series. The project motivation was to explore the different design strategies and fabrication steps enabled by both conventional (mill, drill, and lathe) and additive (3D printing) manufacture of the prototype substrates. Single Point Diamond Turning was used to convert the substrates into mirrors and optical metrology was used to evaluate the different mirror surfaces. The prototype criteria originated from the TSC-1 satellite tertiary mirror, which is designed to minimize the effect of Seidel aberrations before the beam enters the hyperspectral imager. To converge upon the prototype designs, Finite Element Analysis (FEA) was used to evaluate the different physical conditions experienced by the prototypes during manufacture and how these influence the optical performance. The selected designs satisfied the mass and surface displacement criteria of the prototype and were adapted to either the conventional or additive manufacturing process. This paper will present the prototype design process, substrate manufacture, optical fabrication, and an interferometric evaluation of the optical surfaces comparing the conventional and additive manufacturing processes.
The EXOplanet high resolution SPECtrograph (EXOhSPEC) instrument is an echelle spectrograph dedicated to the detection of exoplanets by using the radial velocity method using 2m class telescopes. This spectrograph is specified to provide spectra with a spectral resolution R < 70, 000 over the spectral range from 400 to 700 nm and to reach a shortterm radial velocity precision of 3 m/s. To achieve this the separation between two adjacent spectral orders is specified to be greater than 30 pixels and to enable a wide range of targets the throughput of the instrument is specified to be higher than 4%. We present the results of the optimization of the spectrograph collimator performed and initial tests of its optical performance. First, we consider the spectrograph design and we estimate its theoretical performance. We show that the theoretical image quality is close to the diffraction limit. Second, we describe the method used to perform the tolerancing analyzes using ZEMAX software to estimate the optical performance of the instrument after manufacturing, assembly and alignment. We present the results of the performance budget and we show that the estimated image quality performance of EXOhSPEC are in line with the specifications. Third, we present the results of the stray light analysis and we show that the minimum ratio between the scientific signal and the stray light halo signal is higher than 1,000. Finally, we provide a status on the progress of the EXOhSPEC project and we show the first results obtained with a preliminary version of the prototype.
The National Astronomical Research Institute of Thailand (NARIT) has developed since June 2014 an optical laboratory that comprises all the activities and facilities related to the research and development of new instruments in the following areas: telescope design, high dynamic and high resolution imaging systems and spectrographs. The facilities include ZEMAX and Solidwork software for design and simulation activities as well as an optical room with all the equipment required to develop optical setup with cutting-edge performance.
The current projects include: i) the development of a focal reducer for the 2.3 m Thai National Telescope (TNT), ii) the development of the Evanescent Wave Coronagraph dedicated to the high contrast observations of star close environment and iii) the development of low resolution spectrographs for the Thai National Telescope and for the 0.7 m telescopes of NARIT regional observatories. In each project, our activities start from the instrument optical and mechanical design to the simulation of the performance, the development of the prototype and finally to the final system integration, alignment and tests. Most of the mechanical parts are manufactured by using the facilities of NARIT precision mechanical workshop that includes a 3-axis Computer Numerical Control (CNC) to machine the mechanical structures and a Coordinate Measuring Machine (CMM) to verify the dimensions.
In this paper, we give an overview of the optical laboratory activities and of the associated facilities. We also describe the objective of the current projects, present the specifications and the design of the instruments and establish the status of development and we present our future plans.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.