New hydrodynamic improvements have been developed in order to enable pulsed polishing with the HyDRa system. The operational parameters of the tool are not affected by these modifications, i.e., tool bias and the tool’s floating capability are not lost, and a linear erosion function is produced. The minimum removal is no longer ruled by maximum computer numerical control speed, allowing for high-precision removal that can be taken from zero to the maximum attainable of the tool, in minimum increments of 3.5 nm / ms. This modification also improves the convergence rate of the polishing process toward the desired surface. This development guarantees a high-speed, pulsed operation that enables the tool to be used in a variety of polishing modes, ranging from discrete pixel to continuous pulse width modulation (PWM) polishing. This new capability opens a wide range of applications that can now be tackled with the system, such as zonal and tessellated polishing. PWM capability also allows for simultaneous, multi-head polishing of large optical surfaces.
The Telescopio San Pedro Martir project intends to construct a 6.5m telescope to be installed at the Observatorio Astron´omico Nacional in the Sierra San Pedro M´artir in northern Baja California, Mexico. The project is an association of Mexican institutions, lead by the Instituto Nacional de Astrofısica, Optica y Electronica and UNAM’s Instituto de Astronomia, in partnership with the Smithsonian Astrophysical Observatory and the University of Arizona’s Department of Astronomy and Steward Observatory. The project is advancing through the design stage, having completed five design reviews of different subsystems in 2016 and 2017 (enclosure and services: PDR, CDR; optical design: PDR; optics: progress review; telescope: PDR). Once completed, the partners plan to operate the MMT and TSPM as a binational astrophysical observatory.
KEYWORDS: Mirrors, Actuators, Telescopes, Control systems, Finite element methods, Interfaces, Optical components, Active optics, Temperature metrology
The preliminary design for the f/5 Nasmyth tertiary mirror opto-mechanical configuration for the 6.5m Telescopio San Pedro Mártir (TSPM), to be installed at the Observatorio Astronómico Nacional (OAN) in the Sierra San Pedro Mártir in Baja California is presented. The proposed system consists of support and alignment of the honeycomb mirror within the cell, the correction of the optical surface deformation, both tasks by means of an active push-pull pneumatic system and the correction of the displacements and rotations transferred by the Tube support structure to the configuration by means of electro-mechanical actuators. This optical configuration and four folded Cassegrain stations will be fully defined after first light of the f/5 Cassegrain configuration, so the requirements and considerations of these positions also need to be taken into account.
KEYWORDS: Digital signal processing, Sensors, Electronics, Cameras, Optical filters, Imaging spectroscopy, Infrared cameras, Signal detection, Telescopes, Signal processing
CATAVIÑA is a near-infrared camera system to be operated in conjunction with the existing multi-purpose nearinfrared
optical bench "CAMALEON" in OAN-SPM. Observing modes include direct imaging, spectroscopy, Fabry-
Perot interferometry and polarimetry. This contribution focuses on the optomechanics and detector controller
description of CATAVIÑA, which is planned to start operating later in 2006. The camera consists of an 8 inch LN2
dewar containing a 10 filter carousel, a radiation baffle and the detector circuit board mount. The system is based on a
Rockwell 1024x1024 HgCdTe (HAWAII-I) FPA, operating in the 1 to 2.5 micron window. The detector
controller/readout system was designed and developed at UNAM Instituto de Astronomia. It is based on five Texas
Instruments DSK digital signal processor (DSP) modules. One module generates the detector and ADC-system control,
while the remaining four are in charge of the acquisition of each of the detector's quadrants. Each DSP has a built-in
expanded memory module in order to store more than one image. The detector read-out and signal driver subsystems
are mounted onto the dewar in a "back-pack" fashion, each containing four independent pre-amplifiers, converters and
signal drivers, that communicate through fiber optics with their respective DSPs. This system has the possibility of
programming the offset input voltage and converter gain. The controller software architecture is based on a client/server
model. The client sends commands through the TCP/IP protocol and acquires the image. The server consists of a
microcomputer with an embedded Linux operating system, which runs the main program that receives the user
commands and interacts with the timing and acquisition DSPs. The observer's interface allows for several readout and
image processing modes.
A novel hydrodynamic radial polishing tool (HyDRa) is presented. It performs corrective lapping and fine polishing of diverse materials by means of a low-cost abrasive flux and a hydrodynamic suspension system that avoids contact of the tool with the working surface. With this tool it is possible to polish aspheres and free-form optics on diverse materials and sizes. The functioning principle is based on the generation of a grazing, high-velocity, low-pressure, rotational, variable density, abrasive flux with radial geometry. It has the advantage of avoiding fallen edges during the polishing process as well as reducing tool wear out and deformation. The polishing process is repeatable and achieves high degrees of precision and accuracy on optical and semiconductor surfaces. This tool is particularly useful for polishing thin substrates such as membranes and semiconductors since it can be biased for a non-interactive action on the work piece. An additional advantage of this new tool is the possibility to perform in-process interferometric measurements. Polishing results on assorted materials using HyDRa are presented.
New results using hydrodynamic radial polishing techniques on assorted materials, using HyDRa are presented. This tool performs corrective lapping and fine polishing by means of a low-cost, foamy abrasive flux. The functioning principle is based on the generation of a grazing, high-velocity, low-pressure, rotational, variable density, abrasive flux with radial geometry. It is currently possible to polish aspheres and free-form optics on diverse materials and sizes. This tool is particularly useful for polishing thin substrates such as membranes and semiconductors since it can be biased for a non-interactive action on the work piece. This process also has the advantage of achieving high removal rates. In order to achieve high degrees of accuracy and repeatability in the HyDRa finishing process, fully automated bias and slurry supply units must be incorporated to the polishing system. The air and slurry supply systems are described, as well as operational tool parameters for optimal polishing performance.
A novel hydrodynamic radial polishing tool (HyDRa) is presented. It performs corrective lapping and fine polishing of diverse materials by means of a low-cost abrasive flux and a hydrostatic suspension system that avoids contact of the tool with the working surface. With this tool it is currently possible to polish aspheres and free-form optics of up to 2.5 meters in diameter. It has the advantage of avoiding fallen edges during the polishing process as well as reducing tool wear out and deformation. The functioning principle is based on the generation of a high-velocity, high-pressure abrasive emulsion flux with radial geometry. The polishing process is repeatable and achieves high degrees of precision and accuracy on optical and semiconductor surfaces. An additional advantage of this new tool is the possibility to perform in-process interferometric measurements. Recent results of polished aspheres are discussed.
In order to overcome classic polishing techniques, a novel hydrodynamic radial polishing tool (HyDRa) is presented; it is useful for the corrective lapping and fine polishing of diverse materials by means of a low-cost abrasive flux and a hydrostatic suspension system that avoids contact of the tool with the working surface. This tool enables the work on flat or curved surfaces of currently up to two and a half meters in diameter. It has the advantage of avoiding fallen edges during the polishing process as well as reducing tool wear out and deformation. The functioning principle is based on the generation of a high-velocity, high-pressure, abrasive emulsion flux with radial geometry. The polishing process is repeatable by means of the control of the tool operational parameters, achieving high degrees of precision and accuracy on optical and semiconductor surfaces, with removal rates of up to 9 mm3/hour and promising excellent surface polishing qualities. An additional advantage of this new tool is the possibility to perform interferometric measurements during the polishing process without the need of dismounting the working surface. A series of advantages of this method, numerical simulations and experimental results are described.
HyDRa is a hydrodynamic radial polishing tool ideal for the corrective lapping and fine polishing of diverse materials by means of an accelerated abrasive flux. The roughness of an optical surface is analysed for a continuous manufacturing process, beginning with the basic generation steps up to a finished optical surface. These results were obtained using a Linnik interferometer.
Two main trends presently prevail in ELT design: arrays of hundreds of small (1 - 2 m) hexagonal mirrors and the use of several large (~8m) monolithic mirrors. We present a conceptual study of an off axis 8 m telescope with different mirror options, which can be useful as an experiment towards the design of large multi-mirror telescopes, in terms of different mirror materials, ideas for the optics and new solutions for the telescope mechanical assembly.
We present the dual IR camera CID for the 2.12 m telescope of the
Observatorio Astronomico Nacional de Mexico, IA-UNAM. The system
consists of two separate cameras/spectrographs that operate in
different regions of the IR spectrum. In the near IR, CID comprises a direct imaging camera with wide band filters, a CVF, and a low resolution spectrograph employing an InSb 256 x 256 detector. In the mid IR, CID uses a BIB 128 x 128 detector for direct imaging in 10 and 20 microns. Optics and mechanics of CID were developed at IR-Labs
(Tucson). The electronics was developed by R. Leach (S. Diego). General design, construction of auxiliary optics (oscillating
secondary mirror), necessary modifications and optimization of
the electronics, and acquisition software were carried out at OAN/
UNAM. The compact design of the instruments allow them to share
a single dewar and the cryogenics system.
We report experimental results and analysis about a new hydrodynamic radial tool (HyDra, patent pending), which expels a suspension of water and polishing particles radially on glass. With this method it is possible to locally shape optical surfaces. The depth of material removed by HyDra grows linearly with the time. The removal rate is independent of the velocity between the tool and the glass element. The HyDra has been used to fabricate successfully an optical flat and Schmidt surface.
The trend to minimize the thickness in optical mirrors has led to several practical limits in their fabrication and operation. The design of a flexible membrane mirror segment, which overcomes most of these limitations and can be conformed to giant segmented primary mirrors, is presented.
The segment consists of a lightweight multi-layer hybrid structure, which will permit precise active control of the reflecting surface by means of a continuous elastic medium interface with embedded pneumatic actuators. Conceptual designs, finite element analysis model simulations and experimental results are included.
It has been known that in BIB type, Si:As Mid-IR detectors the internal gain can be strongly related to the internal noise. We prove that by modifying the internal gain it is possible to increase the signal-to-noise ratio to a level which is consistent with poissonian statistics only.
This article presents the design of a capacitive sensor that can detect piston errors as well as lateral displacements between two adjacent MI segments. Due to the measurements' statistical analysis the resolution acquired will be nanometric. This precision is required to achieve the image quality expected for the whole primary segmented-mirror.
We present an active, low cost hydrostatic shoe bearing system for the Mexican Infrared Telescope which solves the suspension and motion of a 100 ton, 7.8 m telescope. Different geometries are analyzed to optimize the shoe's pressure print. These designs offer a self-adjusting action between the shoe's sliding path and the girth track. Different parameters such as pressure, temperature and proximity are measured and implemented into a control system in order to stabilize the bearing from the fluid's thermal viscosity effects. A simple method for fluid injection is discussed.
The Mexican Infrared Telescope is one of the most important projects in the Institute for Astronomy of the National University of Mexico. As part of the design we pretend to simulate different components of the telescope by the Finite Element Method (FEM). One of the most important parts of the structure is the primary mirror support. This structure is under stress, causing deformations in the primary mirror; these deformations shouldn't be over 40 nanometers, which is the maximum permissible tolerance. One of the most interesting subjects to develop in this project is to make the segmented primary mirror to work like if it were a monolithic one. Each segment has six degrees of freedom, whose control needs actuators and sensors with stiff mechanical structures. Our purpose is to achieve these levels of design using FEM aided by computer and we pretend to study several models of the structure array using the Conceptual Design Method, in an effort to optimize the design.
Optical testing of the 2.1-m telescope in San Pedro Martir, Observatorio Astronomico Nacional de Mexico, by the methods of wavefront curvature sensing and bi-Ronchi analysis, has shown that the telescope suffered of large amounts of astigmatism. We identified these as due to improper primary mirror support and developed an active control system to correct for it. The number and position of the actuators were decided in accordance to the flexural modes that needed to be corrected, resulting in a system of 18 pressure controlled pneumatic actuators, with an outer loop that verifies the load at three hard points. A PID algorithm and matrix inversion are fundamental parts of this outer loop, that guarantees that the M1 mirror is tilted as a rigid body to maintain it properly aligned. The successful performance of the system to correct low order aberrations is reported.
We present the Mexican Infrared-Optical New Technology Telescope Project (TIM). The design and construction of a 7.8 m telescope, which will operate at the Observatorio Astronomico Nacional in San Pedro Martir, B.C. (Mexico), are described. The site has been selected based on seeing and sky condition measurements taken for several years. The f/1.5 primary mirror consists of 19 hexagonal off-axis parabolic Zerodur segments. The telescope structure will be alt-az, lightweight, low cost, and high stiffness. It will be supported by hydrostatic bearings. The single secondary will complement a Ritchey-Chretien f/15 design, delivering to Cassegrain focus instrumentation. The telescope will be infrared optimized to allow observations ranging from 0.3 to 20 microns. The TIM mirror cell provides an independent and full active support system for each segment, in order to achieve both, phasing capability and very high quality imaging (0.25 arcsec).
We present the conceptual design of the primary mirror support system of the 7.8 m Mexican Infrared-Optical Telescope. The primary mirror consists of 19 hexagonal off- axis parabolic Zerodur segments, which are carried by a tubular, lightweight and high stiffness cell structure. Each segment is actively supported by 19 pneumatic actuators, that cover the whole back area and provide a uniform force distribution. The array of actuators will be able to correct for high order aberrations. Each of these actuators contains a hydraulic damping system to provide a stiff coupling to the tubular cell to sustain the wind buffeting. The tip/tilt and piston control of each segment will be done through three axial, nanometer resolution position defining actuators. The lateral positioning of each segment is performed through 3 independent electro-mechanical actuators. With the combination of the whole set of actuators and differential positioning sensors, the phasing or coherent superposition of images of the segments, will be more feasible. The whole system will be cost effective, since several subsystems have already been tested on our 2.1 m telescope.
The design concepts of a mid-IR camera/spectrograph, based on a HUGHES/SBRC 320 by 240 Si:As IBC sensor chip assembly (SCA), are presented, The system will operate in the 2 to 28 micrometers wavelength interval and will be optimized in the 10 micrometers regime. This SCA is divided into 32 regions, each with an independent output. The outputs, after being amplified and sampled, are multiplexed into 8 high speed 16 bit A/D converters. The initial configuration allows readout rates of up to 60 frame/s. A higher speed frame readout configuration is foreseen. A 32 bit deep memory and a high speed ALU, synchronized to the detector, will co- add/subtract the frames, making a real time visualization during the integration process possible. The detector, reflective optics, low resolution gratings, several cold stops, baffles, up to 12 filters and a CVF will be allocated in a 10 inch diameter working surface LN2/LHe dewar. The system will be linked to a workstation, providing a user friendly environment. The system is planned to operate at the Observatorio Astronomic Nacional in San Pedro Martir, B.C., Mexico.
We describe the configuration and operation modes of the IR camera/spectrograph: TEQUILA based on a 1024 X 1024 HgCdTe FPA. The optical system will allow three possible modes of operation: direct imaging, low and medium resolution spectroscopy and polarimetry. The basic system is being designed to consist of the following: 1) A LN2 dewar that allocates the FPA together with the preamplifiers and a 24 filter position cylinder. 2) Control and readout electronics based on DSP modules linked to a workstation through fiber optics. 3) An opto-mechanical assembly cooled to -30 degrees that provides an efficient operation of the instrument in its various modes. 4) A control module for the moving parts of the instrument. The opto-mechanical assembly will have the necessary provision to install a scanning Fabry-Perot interferometer and an adaptive optics correction system. The final image acquisition and control of the whole instrument is carried out in a workstation to provide the observer with a friendly environment. The system will operate at the 2.1 m telescope at the Observatorio Astronomico Nacional in San Pedro Martir, B.C. (Mexico), and is intended to be a first-light instrument for the new 7.8m Mexican IR-Optical Telescope.
We are developing an instrument to study the morphology and kinematics of the molecular gas and its interrelationship with the ionized gas in star forming regions, planetary nebulae and supernova remnants in our Galaxy and other galaxies, as well as the kinematics of the IR emitting gas in starburst and interacting galaxies. This instrument consists of a water-free fused silica scanning Fabry-Perot interferometer optimized in the spectral range from 1.5 to 2.4 micrometers with high spectral resolution. It will be installed in the collimated beam of a nearly 2:1 focal reducer, designed for the Cassegrain focus of the 2.1 m telescope of the San Pedro Martir National Astronomical Observatory. Mexico, in its f/7.5 configuration, yielding a field of view of 11.6 arc-min. It will provide direct images as well as interferograms to be focused on a 1024 X 1024 HAWAII array, covering a spectral range from 0.9 to 2.5 micrometers .
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.