We discuss the fabrication and testing of electroformed replica Wolter I optics made from gold-coated lacquered mandrels. We also discuss testing of gold- and palladium-coated lacquered test flats. X-ray (5 keV for Wolter I mirror and 8 to 40 keV for test flats) and optical (Wyko NCP-1 000 profiler) measurements were used to evaluate the mirrors.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.
The alert did not successfully save. Please try again later.
Melville P. Ulmer, Rudy H. Haidle, Robert I. Altkorn, P. Georgopoulos, Brian G. Rodricks, Peter Z. Takacs, "Fabrication and characterization of replicated and lacquer-coated grazing incidence optics for x-ray astronomy," Opt. Eng. 30(8) (1 August 1991) https://doi.org/10.1117/12.55918