1.PrologueMammography is a particularly difficult radiological field and requires highly specialized radiologists to achieve acceptable levels of detection and classification of breast cancer without excessive recalls. A prerequisite is therefore images of the highest possible diagnostic quality and acquired at the lowest possible radiation dose because the breast is an organ that is relatively sensitive to radiation,1 and most of the women in the screening population are healthy. Digital mammography (DM) is still the gold standard breast cancer screening method in most of Europe, with a sensitivity claimed to be around 80%.2 When we in our research group first learned about digital breast tomosynthesis (DBT) during a presentation at the SPIE Medical Imaging symposium in 2004,3 it was obvious that this new technique would become a game changer in breast cancer screening.4 Even non-radiologists were able to detect breast cancers in selected cases, cancers that were missed in the corresponding DM image. 2.Act I: Initial StudiesAfter constructive discussions with representatives from Siemens Healthcare (Erlangen, Germany), it was decided that one of their first DBT prototypes (modified Siemens Mammomat Novation) should be installed in our lab at Skane University Hospital, Malmö, Sweden, in 2006. A number of studies that investigated the potential of tomosynthesis for breast cancer diagnosis compared with mammography were initiated at our lab. Images were collected from women who we believed had the greatest difference in tumor visibility between DBT and DM. In these studies, the inclusion criteria were negative or unclear mammography, in combination with palpable and/or visible lesions on ultrasound (US). The DBT imaging was performed in the view (craniocaudal, CC or mediolateral oblique, MLO) in which the tumor was least visible on DM. If the tumor was only visible on US, the DBT was performed in the MLO view. All available images [including DM, DBT, US, and magnetic resonance imaging (if available)] were collected for these patients together with pathological anatomy diagnosis. The cancers were verified by needle biopsy and pathology and the normal or benign cases with 2-year follow-up. During roughly two and a half years, over 250 cancer cases were collected, forming one of the, at that time, largest collection of tumors imaged with DBT and over 150 normal or benign cases. One of our early examples showing the superiority of DBT compared with DM is presented in Fig. 1. We have used this example in several presentations, and it has convinced even the most skeptical radiologists of the potential of DBT. From our DBT image database, we selected images of 40 confirmed cancers which we used in a pilot study comparing the image quality, defined as cancer visibility, of one-view DBT to one-view DM, to two-view DM, and to two-view DM + US. The image quality was significantly higher for DBT compared with one-view and two-view DM, whereas there was no difference between DBT and two-view DM + US in this study.5 Please note that the DBT images were one-view and in most cases (92.5%) in the MLO projection.5 Compression of the breast during mammographic imaging serves multiple purposes. First, it immobilizes the breast which reduces motion artifacts. Second, the spread of the breast tissue reduces the overlapping of the tissue which may hide tumors. Third, the reduced breast thickness limits the radiation dose to the breast.6,7 However, some women refrain from their screening examination due to the pain caused by the compression.8 As DBT is an imaging technique with depth resolution, it may benefit from reduced compression (and a slightly increased compressed breast thickness). To explore this effect, a study was carried out in which we investigated the image quality at normal compression force compared with half of the normal compression force. Forty-five women were imaged at the two compression levels and with the same acquisition parameters. The results of the study showed no significant difference in image quality between the two compression levels.9 The majority of the women felt that half compression was more comfortable than the standard compression.9 In parallel, we investigated whether breast cancer size and stage could be more accurately assessed with DBT than with DM and US preoperatively. Radiologists measured the tumor extent of 73 breast cancers on DBT, DM, and US and compared the results to pathological size in the resected breast specimen. The tumor outline could be determined in significantly more cases with DBT (86%) compared with DM (67%) and correlated better with pathology (mean deviation from pathology was 1.5 mm for DBT versus 2.2 mm for DM). The study suggested that DBT is superior to DM in assessing preoperative tumor size and hence the T stage of breast cancer and particularly so in women with dense breasts.10 3.Act II: Screening with Digital Breast TomosynthesisSweden has a national screening program that invites all women aged 40 to 74 years to screening with DM every 18 or 24 months, depending on age.11 The participation rate is around 80%. In Sweden and in Europe, mammography is double-read, meaning that two radiologists independently evaluate the images, and a decision on whether to recall the woman for further investigation is reached. If the opinion of the radiologists is discordant, either a consensus discussion or preferably an arbitration should be carried out.6 Encouraged by the positive results of DBT in our early studies, we started planning a prospective population-based screening trial comparing DBT with DM, the Malmö Breast Tomosynthesis Screening Trial (MBTST). The prototype DBT machine was replaced by a commercial machine (Mammomat Inspiration, Siemens Healthcare GmbH, Erlangen, Germany), which could operate in both DM and DBT modes (wide-angle). A random selection of the women invited to attend national breast cancer screening in Malmö also got an invitation to participate in the trial. The women were imaged with two-view DM (CC and MLO projections) and one-view DBT (MLO projection) on a single occasion. The DBT images were acquired with the same beam quality as the DM images, and the automatic exposure control was set to give an average glandular dose of 1.2 mGy per image for DM and 1.6 mGy for one-view DBT (for a standard breast simulated by a 45 mm polymethyl methacrylate phantom6). The radiation dose for one-view DBT was thus around 70% of the dose for two-view DM. The DBT images were acquired with 40% less compression force compared with DM (for the MLO projection), motivated by our earlier image quality assessment of reduced compression. The images from the two modalities were evaluated in two different reading arms, meaning that our trial was the first ever that truly investigated the performance of DBT as a stand-alone modality compared with DM, whereas all other studies up to that time had investigated the added value of DBT, i.e., DBT + DM (or synthetic mammography) versus DM. Our trial included 14,848 women and lasted between January 2010 and February 2015. The results of the trial showed a 34% higher cancer detection rate with DBT compared with DM (8.7 cancers versus 6.5 cancers per 1000 screened women, ), at a slightly higher recall rate (3.6% versus 2.5%) which is well below the acceptable highest level recommended in the European guidelines.6,12,13 The increased cancer detection rate was shown in all breast density categories and not only the densest category, even though the added value of DBT was highest in women in the densest categories.14 The mean size of the cancers detected with DBT was smaller than the mean size of the ones detected by DM, indicating earlier detection. The biological profile of the additional cancers detected with DBT was similar to those detected with DM, which included cancers with the least favorable prognosis.15 The higher recall rate can partly be explained by the lack of reader experience. We observed that the number of false positives associated with DBT decreased with increasing reader experience and could be expected to decrease further in a situation in which screening with DBT is repeated and with previous DBT examinations available for comparison at screen reading.13 An investigation of the interval cancer rate of the women who participated in the MBTST was performed and compared with an age- and screen date–matched control groups that were screened with DM in parallel, at the same location. The analysis showed that the interval cancer rate for the MBTST women was significantly lower, 1.6 per 1000 screened women, compared with 2.8 per 1000 screened women in the control group16 giving 40% lower odds for the women getting an interval cancer following DBT screening. A recent follow-up study of the MBTST cohort revealed lower than normal overall detection rates of less aggressive breast cancer subtypes as well as invasive cancer detection at the following consecutive regular DM screening round, further strengthening the benefit of tomosynthesis screening due to earlier detection of clinically relevant invasive cancers.17 Several papers with a focus on the clinical experiences and lessons learned from the trial have been published and investigated, e.g., reasons for and types of false-positive lesions,18–21 reasons for non-detection at DBT screening,22 and optimization of reading strategies of DBT.23 3.1.Conclusions from the Screening TrialOne-view DBT has a significantly higher cancer detection rate than two-view DM. The compression force with DBT can be reduced compared with DM. The radiation dose of one-view DBT is comparable to two-view DM. To the best of the authors’ knowledge, all other screening trials comparing DBT to DM have been performed with two-view DBT and in combination with either DM or synthetic mammograms. Even if other studies had more extensive imaging protocols (i.e., two-view DBT), the MBTST results were at the same or better performance level.24 We have hence proved that one-view DBT is a highly efficient screening approach with respect to diagnostic performance. 4.EpilogueAlthough the diagnostic performance of DBT is significantly better compared with DM and conditionally recommended over DM by the European Commission Guidelines,25 DM is still the recommended screening modality in Sweden and many other European countries. The disadvantage of DBT is the longer reading time (around 70% longer26,27) which is an obstacle to implementing DBT in resource-starved breast cancer screening programs, especially as the availability of radiologists is already a problem in many countries. Efforts have been made to include AI in the screening workflow to reduce the workload of radiologists. We have studied different scenarios, for example, letting AI replace one reader in a double-reading scenario or excluding low-risk cases from reading.28 Further, we have studied if AI can selectively add DBT in high-risk cases in a primarily DM-based screening situation.29 These studies showed that with AI, it is possible to maintain or even improve the sensitivity of breast cancer screening with DBT without increasing the radiologist workload. The trial examinations now constitute parts of the Malmö Breast Imaging (M-BIG) database for further collaborative work on, e.g., AI and DBT.30 Introducing DBT in national breast cancer screening programs in Europe seems to benefit from being performed in conjunction with a simultaneous introduction of AI to take advantage of the higher diagnostic performance of DBT without increasing the workload of radiologists. DisclosuresAnders Tingberg has had a research grant from Siemens Healthineers. Magnus Dustler, Daniel Förnvik, Pontus Timberg, and Sophia Zackrisson are patent holders (US Patent No. PCT/EP2014/057372). Kristin Johnson is a consultant for Spago Nanomedical. Magnus Dustler and Kristin Johnson have received speaker fees from Siemens Healthcare Healthineers. Sophia Zackrisson has received speaker fees from Siemens Healthineers, Pfizer, and Bayer. Victor Dahlblom declares no competing interests. Code and Data AvailabilityData sharing is not applicable to this article, as no new data were created or analyzed. AcknowledgmentsWe wish to acknowledge Siemens Healthineers for providing the DBT prototype (Mammomat Novation) and the clinical DBT machine (Mammomat Inspiration), as well as financial support, and ScreenPoint Medical for providing the Transpara system and technical support. We also express our sincere gratitude to Dr. Ingvar Andersson, a pioneer in both mammography and tomosynthesis and in many respects the person who sparked the idea of the MBTST. Thanks also to the many talented people involved over the years in our multidisciplinary group, Lund University Breast Cancer Imaging Group, LUCI.31 This work was funded by Region Skåne (Regionalt forskningsstöd and USVE-utrymme), the Swedish Cancer Society, the Swedish Research Council, Governmental Funding for Clinical Research (ALF), and Allmänna Sjukhusets i Malmö Stiftelse för Bekämpande av Cancer (Malmö General Hospital Cancer Foundation). ReferencesICRP, ICRP Publication 103: the 2007 Recommendations of the International Commission on Radiological Protection, Pergamon Press, Oxford
(2007). Google Scholar
S. Weigel et al.,
“Digital mammography screening: sensitivity of the programme dependent on breast density,”
Eur Radiol, 27
(7), 2744
–2751 https://doi.org/10.1007/s00330-016-4636-4
(2017).
Google Scholar
T. Wu et al.,
“Digital tomosynthesis mammography using a parallel maximum likelihood reconstruction method,”
Proc. SPIE, 5368 1
–11 https://doi.org/10.1117/12.534446 PSISDG 0277-786X
(2004).
Google Scholar
A. Tingberg and S. Zackrisson,
“Digital mammography and tomosynthesis for breast cancer diagnosis,”
Expert Opin. Med. Diagn., 5
(6), 517
–526 https://doi.org/10.1517/17530059.2011.616492
(2011).
Google Scholar
I. Andersson et al.,
“Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings,”
Eur. Radiol., 18
(12), 2817
–2825 https://doi.org/10.1007/s00330-008-1076-9
(2008).
Google Scholar
N. Perry et al.,
“European guidelines for quality assurance in breast cancer screening and diagnosis. Fourth edition—summary document,”
Ann. Oncol., 19
(4), 614
–622 https://doi.org/10.1093/annonc/mdm481 ANONE2 0923-7534
(2008).
Google Scholar
Jr. R. S. Saunders and E. Samei,
“The effect of breast compression on mass conspicuity in digital mammography,”
Med. Phys., 35
(10), 4464
–4473 https://doi.org/10.1118/1.2977600 MPHYA6 0094-2405
(2008).
Google Scholar
P. Whelehan et al.,
“The effect of mammography pain on repeat participation in breast cancer screening: a systematic review,”
Breast, 22
(4), 389
–394 https://doi.org/10.1016/j.breast.2013.03.003
(2013).
Google Scholar
D. Förnvik et al.,
“The effect of reduced breast compression in breast tomosynthesis: human observer study using clinical cases,”
Radiat. Prot. Dosimetry, 139
(1-3), 118
–123 https://doi.org/10.1093/rpd/ncq103 RPDODE 0144-8420
(2010).
Google Scholar
D. Förnvik et al.,
“Breast tomosynthesis: accuracy of tumor measurement compared with digital mammography and ultrasonography,”
Acta Radiol., 51
(3), 240
–247 https://doi.org/10.3109/02841850903524447
(2010).
Google Scholar
Socialstyrelsen - The Swedish National Board of Health and Welfare,
“Socialstyrelsens föreskrifter och allmänna råd om villkor för avgiftsfri screening,”
(2019). Google Scholar
K. Lang et al.,
“Performance of one-view breast tomosynthesis as a stand-alone breast cancer screening modality: results from the Malmo Breast Tomosynthesis Screening Trial, a population-based study,”
Eur. Radiol., 26
(1), 184
–190 https://doi.org/10.1007/s00330-015-3803-3
(2016).
Google Scholar
S. Zackrisson et al.,
“One-view breast tomosynthesis versus two-view mammography in the Malmo Breast Tomosynthesis Screening Trial (MBTST): a prospective, population-based, diagnostic accuracy study,”
Lancet Oncol., 19
(11), 1493
–1503 https://doi.org/10.1016/S1470-2045(18)30521-7 LOANBN 1470-2045
(2018).
Google Scholar
J. Olinder et al.,
“Impact of breast density on diagnostic accuracy in digital breast tomosynthesis versus digital mammography: results from a European screening trial,”
Breast Cancer Res., 25
(1), 116 https://doi.org/10.1186/s13058-023-01712-6 BCTRD6
(2023).
Google Scholar
K. Johnson et al.,
“Tumor characteristics and molecular subtypes in breast cancer screening with digital breast tomosynthesis: the Malmö Breast Tomosynthesis Screening Trial,”
Radiology, 293
(2), 273
–281 https://doi.org/10.1148/radiol.2019190132 RADLAX 0033-8419
(2019).
Google Scholar
K. Johnson et al.,
“Interval breast cancer rates and tumor characteristics in the prospective population-based Malmö Breast Tomosynthesis Screening Trial,”
Radiology, 299
(3), 559
–567 https://doi.org/10.1148/radiol.2021204106 RADLAX 0033-8419
(2021).
Google Scholar
A. Jogi et al.,
“Assessing digital breast tomosynthesis impact on early cancer detection: insights from consecutive screening,”
Radiology, 312
(1), e233417 https://doi.org/10.1148/radiol.233417 RADLAX 0033-8419
(2024).
Google Scholar
A. Rosso et al.,
“Factors affecting recall rate and false positive fraction in breast cancer screening with breast tomosynthesis—a statistical approach,”
Breast, 24
(5), 680
–686 https://doi.org/10.1016/j.breast.2015.08.007
(2015).
Google Scholar
K. Lang et al.,
“False positives in breast cancer screening with one-view breast tomosynthesis: an analysis of findings leading to recall, work-up and biopsy rates in the Malmo Breast Tomosynthesis Screening Trial,”
Eur. Radiol., 26
(11), 3899
–3907 https://doi.org/10.1007/s00330-016-4265-y
(2016).
Google Scholar
N. Houssami et al.,
“Digital breast tomosynthesis (3D-mammography) screening: a pictorial review of screen-detected cancers and false recalls attributed to tomosynthesis in prospective screening trials,”
Breast, 26 119
–134 https://doi.org/10.1016/j.breast.2016.01.007
(2016).
Google Scholar
K. Johnson et al.,
“False-positive recalls in the prospective Malmo Breast Tomosynthesis Screening Trial,”
Eur. Radiol., 33 8089
–8099 https://doi.org/10.1007/s00330-023-09705-x
(2023).
Google Scholar
K. Lang, I. Andersson and S. Zackrisson,
“Breast cancer detection in digital breast tomosynthesis and digital mammography—a side-by-side review of discrepant cases,”
Br. J. Radiol., 87 20140080 https://doi.org/10.1259/bjr.20140080 BJRAAP 0007-1285
(2014).
Google Scholar
P. Timberg et al.,
“Investigation of viewing procedures for interpretation of breast tomosynthesis image volumes: a detection-task study with eye tracking,”
Eur. Radiol., 23
(4), 997
–1005 https://doi.org/10.1007/s00330-012-2675-z
(2013).
Google Scholar
S. Libesman et al.,
“An individual participant data meta-analysis of breast cancer detection and recall rates for digital breast tomosynthesis versus digital mammography population screening,”
Clin Breast Cancer, 22
(5), e647
–e654 https://doi.org/10.1016/j.clbc.2022.02.005
(2022).
Google Scholar
, “European guidelines on breast cancer screening and diagnosis - 5. Use of tomosynthesis,”
https://cancer-screening-and-care.jrc.ec.europa.eu/en/ecibc/european-breast-cancer-guidelines?topic=65&usertype=60&updatef2=0
().
Google Scholar
P. Clauser et al.,
“Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications,”
Eur. J. Radiol., 85
(12), 2161
–2168 https://doi.org/10.1016/j.ejrad.2016.10.004 EJRADR 0720-048X
(2016).
Google Scholar
H. S. Aase et al.,
“A randomized controlled trial of digital breast tomosynthesis versus digital mammography in population-based screening in Bergen: interim analysis of performance indicators from the To-Be trial,”
Eur. Radiol., 29
(3), 1175
–1186 https://doi.org/10.1007/s00330-018-5690-x
(2019).
Google Scholar
V. Dahlblom et al.,
“Breast cancer screening with digital breast tomosynthesis: comparison of different reading strategies implementing artificial intelligence,”
Eur. Radiol., 33
(5), 3754
–3765 https://doi.org/10.1007/s00330-022-09316-y
(2023).
Google Scholar
V. Dahlblom et al.,
“Personalized breast cancer screening with selective addition of digital breast tomosynthesis through artificial intelligence,”
J. Med. Imaging, 10
(Suppl. 2), S22408 https://doi.org/10.1117/1.JMI.10.S2.S22408 JMEIET 0920-5497
(2023).
Google Scholar
V. Dahlblom et al.,
“Malmo Breast ImaginG database: objectives and development,”
J. Med. Imaging, 10
(6), 061402 https://doi.org/10.1117/1.JMI.10.6.061402 JMEIET 0920-5497
(2023).
Google Scholar
BiographyAnders Tingberg, PhD, is an associate professor in medical radiation physics at the Department of Translational Medicine, Lund University, Malmö, Sweden; a certified medical physicist at Skåne University Hospital; and a member of LUCI, Lund University Breast Cancer Imaging. He has authored or coauthored more than 130 peer-reviewed or conference papers. His main research focus is breast imaging, especially breast tomosynthesis and the integration of artificial intelligence in screening. He is a senior member of SPIE. Victor Dahlblom received his bachelor’s and master’s degrees in medicine from the University of Copenhagen, Denmark, in 2010 and 2013, respectively, and his BSc degree in technology focused on biomedical engineering from Lund University in 2015. He received his PhD in 2024 in diagnostic radiology in the Department of Translational Medicine, Lund University, Malmö, Sweden, and a radiology resident at Skåne University Hospital Malmö, Sweden. His research focuses on the evaluation of artificial intelligence systems in breast cancer screening and development of the Malmo Breast ImaginG, breast imaging database. Magnus Dustler received his MSc degree in engineering physics and his PhD in medical radiation physics both from Lund University, Sweden. He is an associate professor in diagnostic radiology in the Department of Translational Medicine, Lund University, Malmö, Sweden, and a member of LUCI. His research focuses on breast imaging, especially on novel imaging methods, computer modeling of tissue, and validation and integration of artificial intelligence in screening. Daniel Förnvik received his PhD in medical radiation physics from Lund University and has done a postdoc at Kyoto University, Japan. He is an associate professor in medical radiation physics in the Department of Translational Medicine, Lund University, Malmö, Sweden, and a certified medical physicist at Skåne University Hospital. His research area is breast imaging, with a special focus on breast density. Kristin Johnson, MD, PhD, is a researcher in diagnostic radiology at the Department of Translational Medicine at Lund University and a consultant radiologist at Skåne University Hospital, Sweden. She is currently pursuing a postdoc at UZ Leuven and KU Leuven, Belgium. Her research is focused on breast imaging, breast cancer screening, and abdominal imaging. Pontus Timberg, PhD, is a certified medical physicist, at Skåne University Hospital, and a member of LUCI. He is affiliated with medical radiation physics at the Department of Translational Medicine, Lund University, Malmö, Sweden. His research focuses on breast imaging, image perception, and observer performance. Sophia Zackrisson, MD, PhD, is a professor of radiology and head of diagnostic radiology in the Department of Translational Medicine at Lund University, and a senior consultant radiologist at Skåne University Hospital in Malmö, Sweden. She is the deputy director of the Lund University Cancer Center, one of the strategic research areas, assembling all cancer researchers at the university. She is the author of >140 journal papers and holds several research awards. Her main interest is cancer imaging, with a focus on breast cancer screening and prostate and gastrointestinal imaging methods. She is the president of the Swedish Society of Breast Radiology and a board member of the European Society of Breast Imaging. |
Digital breast tomosynthesis
Breast cancer
Breast
Cancer
Cancer detection
Mammography
Tomosynthesis