Paper
12 May 2016 Multi-view coded aperture coherent scatter tomography
Author Affiliations +
Abstract
We use coded apertures and multiple views to create a compressive coherent scatter computed tomography (CSCT) system. Compared with other CSCT systems, we reduce object dose and scan time. Previous work on coded aperture tomography resulted in a resolution anisotropy that caused poor or unusable momentum transfer resolution in certain cases. Complimentary and multiple views resolve the resolution issues, while still providing the ability to perform snapshot tomography by adding sources and detectors.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Andrew D. Holmgren, Ikenna Odinaka, Joel A. Greenberg, and David J. Brady "Multi-view coded aperture coherent scatter tomography", Proc. SPIE 9847, Anomaly Detection and Imaging with X-Rays (ADIX), 98470A (12 May 2016); https://doi.org/10.1117/12.2223871
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Coded apertures

Tomography

X-rays

Fluctuations and noise

Calibration

Signal detection

RELATED CONTENT

Coded aperture x-ray scatter tomography
Proceedings of SPIE (March 07 2014)
A Comparison Of The Number Of Rays Vs The Number...
Proceedings of SPIE (December 27 1977)
Experimental evaluation of the pile up trigger method in a...
Proceedings of SPIE (February 23 2012)
A new scanning device in CT with dose reduction potential
Proceedings of SPIE (March 02 2006)
Coded aperture computed tomography
Proceedings of SPIE (August 24 2009)

Back to Top