Paper
18 March 2015 Which pivot calibration?
Author Affiliations +
Abstract
Estimating the location of a tracked tool’s tip relative to its Dynamic Reference Frame (DRF) and localizing a specific point in a tracking system’s coordinate frame are fundamental tasks in image-guided procedures. The most common approach to estimating these values is by pivoting a tool around a fixed point. The transformations from the tracking system’s frame to the tool's DRF are the input. The output is the translation from the DRF to the tool’s tip and the translation from the tracker’s frame to the pivoting point. While the input and output are unique, there are multiple mathematical formulations for performing this estimation task. The question is, are these formulations equivalent in terms of precision and accuracy? In this work we empirically evaluate three common formulations, a geometry based sphere fitting formulation and two algebraic formulations. In addition we evaluate robust variants of these formulations using the RANSAC framework. Our evaluation shows that the algebraic formulations yield estimates that are more precise and accurate than the sphere fitting formulation. Using the Vicra optical tracking system from Northern Digital Inc., we observed that the algebraic approaches have a mean(std) precision of 0.25(0.11)mm localizing the pivoting point relative to the tracked DRF, and yield a fiducial registration error with a mean(std) 0.15(0.08)mm when registering a precisely constructed divot phantom to the localized points in the tracking system's frame. The sphere fitting formulation yielded less precise and accurate results with a mean(std) of 0.35(0.21)mm for precision and 0.25(0.14)mm for accuracy. The robust versions of these formulations yield similar results even when the data is contaminated with 30% outliers.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ziv Yaniv "Which pivot calibration?", Proc. SPIE 9415, Medical Imaging 2015: Image-Guided Procedures, Robotic Interventions, and Modeling, 941527 (18 March 2015); https://doi.org/10.1117/12.2081348
Lens.org Logo
CITATIONS
Cited by 25 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Optical spheres

Adaptive optics

Optical tracking

Data acquisition

Data modeling

Robotics

RELATED CONTENT

A framework for measuring TRE at the tip of an...
Proceedings of SPIE (March 12 2013)
3D modeling from AFM measurements
Proceedings of SPIE (June 05 2001)
Fully automatic 3D digitization of unknown objects
Proceedings of SPIE (January 28 2010)
Hybrid tracking system for flexible endoscopes
Proceedings of SPIE (May 05 2004)

Back to Top