Based on the technology of the spectrum absorption and the FBG, the monitoring system realize on line detection of the concentration of methane and oxygen, the temperature and the pressure of the gas in pipeline, and in order to improve the accuracy of the gas detection, we induce the compensation to the gas concentration using the data of the temperature and the pressure. In order to have a effective utilization of the methane in the coal mine gas drainage system, we have to have a accurate measurements of the concentration, the temperature and the pressure of the gas in pipeline. At the same time the dynamic monitoring of the concentration of Oxygen is a sign of the leakage of the pump. This paper gave some data detected in the field of the coal mine gas drainage system.
|