Paper
23 March 2010 A balanced filterless K-edge energy window multilayer detector for dual energy computed tomography
Nicholas Allec, Karim S. Karim
Author Affiliations +
Abstract
Ross (or balanced) filter-based systems have been studied extensively in the past, however they have only recently been studied for medical applications such as computed tomography and contrast-enhanced mammography. Balanced filters are filters composed of different materials which have thicknesses designed to match the attenuation for all radiation energies except those within a certain energy window (between the K-edges of the filter materials). Images obtained using different filters to attenuate the incident x-rays can be subtracted to obtain an image which contains information solely within the energy window. The disadvantage of this image acquisition method is the requirement of a separate exposure for each filter. This can lead to motion artifacts in the resulting image for example due to cardiac, respiratory, or patient movement. In this paper we investigate a filterless, multilayer detector design using the general concept of balanced filters. In the proposed detector, energy discrimination is achieved using stacked layers of different conversion materials. Similar to how the thicknesses of balanced filters are chosen, the thicknesses of the conversion layers are designed to match the attenuation of x-rays except between the K-edges of the conversion materials. Motion artifacts are suppressed in the final image due to the simultaneous acquisition of images on all layers during a single exposure. The proposed multilayer design can be used for a number of applications depending on the energy range of interest. To study the proposed design, we consider dual energy computed tomography (CT) using a gadolinium-based contrast agent.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Nicholas Allec and Karim S. Karim "A balanced filterless K-edge energy window multilayer detector for dual energy computed tomography", Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 76224G (23 March 2010); https://doi.org/10.1117/12.844016
Lens.org Logo
CITATIONS
Cited by 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Signal attenuation

X-rays

Signal detection

Dual energy imaging

Optical filters

Photon transport

Back to Top