Paper
8 September 2009 Proposed traceable structural resolution protocols for 3D imaging systems
Author Affiliations +
Abstract
A protocol for determining structural resolution using a potentially-traceable reference material is proposed. Where possible, terminology was selected to conform to those published in ISO JCGM 200:2008 (VIM) and ASTM E 2544-08 documents. The concepts of resolvability and edge width are introduced to more completely describe the ability of an optical non-contact 3D imaging system to resolve small features. A distinction is made between 3D range cameras, that obtain spatial data from the total field of view at once, and 3D range scanners, that accumulate spatial data for the total field of view over time. The protocol is presented through the evaluation of a 3D laser line range scanner.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David MacKinnon, J.-Angelo Beraldin, Luc Cournoyer, Benjamin Carrier, and François Blais "Proposed traceable structural resolution protocols for 3D imaging systems", Proc. SPIE 7447, Videometrics, Range Imaging, and Applications X, 744704 (8 September 2009); https://doi.org/10.1117/12.824458
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Computer aided design

3D scanning

Imaging systems

Image resolution

Laser scanners

Solid modeling

Stereoscopy

RELATED CONTENT