Paper
11 June 2007 Four channels cross correlation method for high sensitivity current noise measurements
C. Ciofi, G. Scandurra, R. Merlino, G. Cannatà, G. Giusi
Author Affiliations +
Proceedings Volume 6600, Noise and Fluctuations in Circuits, Devices, and Materials; 660012 (2007) https://doi.org/10.1117/12.725528
Event: SPIE Fourth International Symposium on Fluctuations and Noise, 2007, Florence, Italy
Abstract
We demonstrate how it is possible to increase the sensitivity of current noise measurement systems by exploiting the properties of a differential transconductance amplifier coupled with a four channels measurement system. In particular, it is demonstrated that, in proper conditions and by a proper elaboration of the acquired signals, the noise contribution coming from the active and passive devices that make up the transresistance amplifier can be virtually eliminated. The method is validated by means of actual measurements in order to demonstrate the effectiveness of the approach we propose.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
C. Ciofi, G. Scandurra, R. Merlino, G. Cannatà, and G. Giusi "Four channels cross correlation method for high sensitivity current noise measurements", Proc. SPIE 6600, Noise and Fluctuations in Circuits, Devices, and Materials, 660012 (11 June 2007); https://doi.org/10.1117/12.725528
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.