Paper
21 June 2006 Depth quantificaton for inhomogeneities within semisolid materials using 3D pulsed digital holography
Maria del Socorro Hernández-Montes, Fernando Mendoza Santoyo, Carlos Pérez-López, Ramón Rodríguez Vera
Author Affiliations +
Proceedings Volume 6345, Seventh International Conference on Vibration Measurements by Laser Techniques: Advances and Applications; 63450F (2006) https://doi.org/10.1117/12.693154
Event: Seventh International Conference on Vibration Measurements by Laser Techniques: Advances and Applications, 2006, Ancona, Italy
Abstract
A 3D experimental arrangement for pulsed digital holography is used to measure the depth position for both a glass sphere and tumor tissue, immersed in a semi-solid gel model. A master gel, one without inhomogeneities, is set to resonate via sound waves generated with a conventional speaker placed a few centimeters away from the gel container. Later an identical prepared gel with an inhomogeneity is placed in the original set up and interrogated at the same resonant frequency. On comparison and using only an out of plane sensitive set up it is possible to measure the displacement of the gel surface, indicating the presence of an internal inhomogeneity. However the depth position cannot be measured accurately since the out of plane component has also the contribution of the in-plane surface displacements. With the information gathered from the 3D pulsed digital holography set up it is possible to obtain three sensitivity vectors that serve to independently separate the contributions from each of the three x, y and z components of the vibration displacement, for the same exciting mechanical wave. It is then possible to build individual maps of displacement along the three rectangular axes and thus measure accurately the depth position of the inhomogeneity. Results from the optical data were correlated to the measured position for different inhomogeneity types, sizes and depths and on comparison an error in the position of less than 1% was found. This optical non invasive method is able to accurately find the inhomogeneity and its position within the gel making it a promising method for the study of mammal tumors, representing and alternative to the traditional invasive methods.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Maria del Socorro Hernández-Montes, Fernando Mendoza Santoyo, Carlos Pérez-López, and Ramón Rodríguez Vera "Depth quantificaton for inhomogeneities within semisolid materials using 3D pulsed digital holography", Proc. SPIE 6345, Seventh International Conference on Vibration Measurements by Laser Techniques: Advances and Applications, 63450F (21 June 2006); https://doi.org/10.1117/12.693154
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Digital holography

Tumors

Holograms

Glasses

Pulsed laser operation

3D modeling

Calibration

Back to Top