26 October 2004 Dark current, sensitivity, and image lag comparison of mercuric iodide and lead iodide x-ray imagers
George Zentai, Larry D. Partain, Raisa Pavlyuchkova, Cesar H. Proano, Michael M. Schieber, Jerry Thomas
Author Affiliations +
Abstract
Mercuric iodide (HgI2) and lead iodide (PbI2) materials as direct converter layers for digital x-ray imaging have been studied for several years. This paper present results of basic imaging parameters by comparing dark current, sensitivity and image lag properties of these materials. A difficult challenge of both lead iodide and mercuric iodide photon detectors is higher than desired leakage currents. These currents are influenced by factors such as applied electrical field, layer thickness, layer density, electrode structure and material purity. Minimizing the leakage current must also be achieved without adversely affecting charge transport, which plays a large role in gain and is also influenced by these parameters. New deposition technologies have been developed through which the leakage current has now decreased by more than an order of magnitude while showing no negative affects on gain. Other challenges relate to increasing film thickness without degrading electrical properties. The image lag of the polycrystalline PbI2 is much larger than that of the polycrystalline HgI2 material, however, no significant image lag is observed for single crystal PbI2. Optical microscopy and SEM studies showed that the polycrystalline PbI2 has a low density, randomly oriented morphology with small crystallites while the best HgI2 has a much better oriented (single crystal-like) structure. We believe that the long image lag can be attributed to the large number of deep defect states generated on the surface of the small PbI2 crystallites. The imagers were evaluated for both radiographic and fluoroscopic imaging modes. MTF was measured as a function of the spatial frequency. The MTF data were compared to values published in the literature for indirect detectors (CsI) and direct detectors (a-Se). Resolution tests on resolution target phantoms showed that for both materials resolution is mostly limited by the TFT array Nyquist frequency.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
George Zentai, Larry D. Partain, Raisa Pavlyuchkova, Cesar H. Proano, Michael M. Schieber, and Jerry Thomas "Dark current, sensitivity, and image lag comparison of mercuric iodide and lead iodide x-ray imagers", Proc. SPIE 5541, Penetrating Radiation Systems and Applications VI, (26 October 2004); https://doi.org/10.1117/12.581223
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Imaging systems

Crystals

X-ray imaging

Modulation transfer functions

Lead

X-rays

Sensors

Back to Top