Paper
12 May 2004 Shape-based discriminative analysis of combined bilateral hippocampi using multiple object alignment
Li Shen, Fillia Makedon, Andrew Saykin
Author Affiliations +
Abstract
Shape analysis of hippocampi in schizophrenia has been preformed previously using the spherical harmonic SPHARM description. In these studies, the left and right hippocampi are aligned independently and the spatial relation between them is not explored. This paper presents a new SPHARM-based technique which examines not only the individual shape information of the two hippocampi but also the spatial relation between them. The left and right hippocampi are treated as a single shape configuration. A ploy-shape alignment algorithm is developed for aligning configurations of multiple SPHARM surfaces as follows: (1) the total volume is normalized; (2) the parameter space is aligned for creating the surface correspondence; (3) landmarks are created by a uniform sampling of multiple surfaces for each configuration; (4) a quaternion-based algorithm is employed to align each landmark representation to the mean configuration through the least square rotation and translation iteratively until the mean converges. After applying the poly-shape alignment algorithm, a point distribution model is applied to aligned landmarks for feature extraction. Classification is performed using Fisher's linear discriminant with an effective feature selection scheme. Applying the above procedure to our hippocampal data (14 controls versus 25 schizophrenics, all right-handed males), we achieve the best cross-validation accuracy of 92%, supporting the idea that the whole shape configuration of the two hippocampi provides valuable information in detecting schizophrenia. The results of an ROC analysis and a visualization of discriminative patterns are also included.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Li Shen, Fillia Makedon, and Andrew Saykin "Shape-based discriminative analysis of combined bilateral hippocampi using multiple object alignment", Proc. SPIE 5370, Medical Imaging 2004: Image Processing, (12 May 2004); https://doi.org/10.1117/12.536223
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ferroelectric LCDs

Visualization

Control systems

Principal component analysis

Shape analysis

Spherical lenses

Feature selection

Back to Top