Paper
2 June 2003 Resist compacting under SEM E-Beam
Author Affiliations +
Abstract
Resist critical dimensions (CD) and thickness are usually obtained by in-line CD SEM or in-line optical metrology measurements but varification or calibration of these is typically achived by cross sectional SEM. As we push CDs to 100nm and beyound, descrepencies between these two sources data can constitute a large percentage of the target dimension. Particularly for 193nm resists, the CD shrinkage under SEM has been well characterized, but the vertical and horizontal compaction behavior in across sectional SEM has not been explored. In this paper, the discussion is divided into two parts. One is for bulk resist and another is for patterned resist. For bulk case, the the only variable is vertical thickness. The experiments for I-line, 248nm and 193nm resist indicated that the resist thickness from the cross sectional image is strongly dependent on the resist polymer structure, the SEM conditions and the interrogration time under SEM E-beam. Therefore, the thickness comparison between optical and electronic is not always meaningful because the cross sectional thickness often shows a low thickness than the optically determined value. We have determined the optimum SEM condition to minimize vertical compaction. There are two variables for patterned resist, vertical thickness and lateral CD size. Our experiments for I-line and 248nm resists exhibited that the patterned resist thickness can be 30% lower than the optical thickness. However, the lateral CD sizes showed less variation relative to the different SEM conditions. The unique behaviors of 193nm patterned resist are also displayed and discussed in this paper. Based on all experimental data, different SEM conditions are recommended based on different purposes to generate accurate cross sectional resist images.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yiming Gu, Dyiann Chou, and John L. Sturtevant "Resist compacting under SEM E-Beam", Proc. SPIE 5038, Metrology, Inspection, and Process Control for Microlithography XVII, (2 June 2003); https://doi.org/10.1117/12.483432
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scanning electron microscopy

Critical dimension metrology

Deep ultraviolet

Image quality

Cadmium

Optical testing

Polymers

Back to Top