Paper
1 August 2003 Electromagnetic compatibility management for fast diagnostic design
Joel Raimbourg
Author Affiliations +
Proceedings Volume 4948, 25th International Congress on High-Speed Photography and Photonics; (2003) https://doi.org/10.1117/12.516786
Event: 25th international Congress on High-Speed photography and Photonics, 2002, Beaune, France
Abstract
This paper presents an overview of electromagnetic compatibility (EMC) management for fast diagnostic design. In research centers, we often use prototypes or very specific diagnostics which exist in very few small number. Technical specifications are close to physical limits or hard to reach. It takes a considerable effort to put them in working order. Often, there is no real expertise on EMC. However, electromagnetic interference (EMI) could ruin the system. At best, it will decrease the signal to noise ratio. In the worst cases, the diagnostic will not work or could be destroyed. Generally, EMI occurs when an electrical disturbance from either natural phenomena (electrostatic discharge, lightning, and so on) or electronic equipment causes an undesired response in another piece of equipment. EMC is just the opposite of EMI; that is, EMC is said to exist when no equipment or system causes EMI to other equipment or systems. The three elements of an EMI episode are the source, the victim, and the coupling path. We will present and detail the classical approach in EMC. This approach can be successfully applied for installations where a single engineering entity has the authority to prescribe and enforce a certain compatibility level. We illustrate this approach with an example: EMC on plasma diagnostics in a 10 - 60 kiloJoule class laser. Up to now, all the diagnostics developed for laser produced plasmas have mainly been designed without taking into account the direct effects of radiated energies emitted by the plasma itself on the diagnostic active components. Our laser facility, the LIL, will be able to focus up to 60 kJ into a volume of less than 1 mm3. We have to evaluate the electromagnetic pulse (EMP) inside and outside the target chamber where diagnostics, cables and oscilloscopes will be installed. We performed experiments at the Omega laser facility at the University of Rochester. We designed a specific electromagnetic probe for pulse measurement with a rise time down to 100 ps. We will discuss problems induced by the grounding approach and show how to cope with them.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Joel Raimbourg "Electromagnetic compatibility management for fast diagnostic design", Proc. SPIE 4948, 25th International Congress on High-Speed Photography and Photonics, (1 August 2003); https://doi.org/10.1117/12.516786
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Diagnostics

Electromagnetism

Electromagnetic coupling

Connectors

Oscilloscopes

Laser development

Plasma

RELATED CONTENT

Target alignment on the LIL laser facility
Proceedings of SPIE (May 16 2007)
LASERIX a European versatile high rep rate facility for...
Proceedings of SPIE (September 26 2007)
Time fiducial on the LIL facility at CEA/CESTA
Proceedings of SPIE (May 16 2007)

Back to Top