Paper
20 December 2001 ComIXS: a compact inelastic x-ray spectrometer
Daniele Cocco, Maurizio Matteucci, Kevin C. Prince, Marco Zangrando
Author Affiliations +
Abstract
Soft x-ray emission spectroscopy is a well established technique, which has seen increased interest in recent years due to the development of high brilliance synchrotron radiation facilities. Emission spectra are obtained when a hole is created by impinging photons, and an electron from the valence band decays into the core hole emitting its excess energy radiatively. The fluorescence yield is intrinsically low in the range of soft x-rays, usually less than about 0.5%, since the most probable decay channels are radiationless channels like Coster Kronig and Auger processes. Emission is over all space, but only a restricted solid angle can be collected and this further reduces the efficiency of the instrumentation. Moreover, the emitted photons must be energy selected, and this involves the use of soft x-ray monochromators with good resolving power. We designed a photon spectrometer to be located in the experimental chamber of one of ELETTRA's beamlines (BACH) to perform inelastic X-ray scattering measurement in the energy range 20-1200 eV with relatively high resolving power (above 2000 in most of the range). The spectrometer is based on two interchangeable mechanically ruled spherical VLS gratings with blaze profile of the grooves. The diffracted photons are collected by a back illuminated CCD of 1300X1340 pixels, each of 20X20 micrometers 2 dimension. The two interchangeable gratings are inserted in or removed from the beam by manual translation and are kept fixed during the measurement. The energy scan (or selection) is made by a mono-dimensional translation of the CCD. To cover the whole energy range, including the zero order light, only a small movement (about 7 cm of linear translation) of the detector is necessary. No detector rotation or bi-dimensional displacement is needed. Since the size of the CCD is quite large, it is possible to collect, in a single shot, a very large photon energy window, about 20-30% of the full energy range of each grating. The optical layout and the expected performances are reported.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Daniele Cocco, Maurizio Matteucci, Kevin C. Prince, and Marco Zangrando "ComIXS: a compact inelastic x-ray spectrometer", Proc. SPIE 4506, Soft X-Ray and EUV Imaging Systems II, (20 December 2001); https://doi.org/10.1117/12.450944
Lens.org Logo
CITATIONS
Cited by 12 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Photons

Spectral resolution

Sensors

Spatial resolution

Charge-coupled devices

Spectroscopy

X-rays

RELATED CONTENT

Arcus an ISS attached high resolution x ray grating...
Proceedings of SPIE (July 24 2014)
The x-ray microcalorimeter spectrometer onboard Athena
Proceedings of SPIE (September 17 2012)
ASTRO-E/XRS calibration program and results
Proceedings of SPIE (October 22 1999)
The use of CCDs and EM CCDs for future soft...
Proceedings of SPIE (September 17 2012)

Back to Top