Paper
8 January 1996 HA films created by PLD: results of physical and biocompatible tests
Miroslav Jelinek, Tatjana Dostalova M.D., Costas Fotakis, Jirina Bartova, Christos Grivas, Lucia Himmlova, Lubomir Jastrabik, Vaclav Studnicka
Author Affiliations +
Abstract
Thin films of hydroxylapatite were created on Ti and Ti6A14V flat substrates by excimer laser ablation. Wide scale of deposition conditions were varied as deposition atmosphere (vacuum, pure water vapors, mixture of Ar and water vapors), substrate temperature, target-substrate distance and energy density. Results of physical, mechanical and biological analysis are summarized. No clear correlation between physical and mechanical properties and results of biological tests (activity of T-lymphocytes) were found.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Miroslav Jelinek, Tatjana Dostalova M.D., Costas Fotakis, Jirina Bartova, Christos Grivas, Lucia Himmlova, Lubomir Jastrabik, and Vaclav Studnicka "HA films created by PLD: results of physical and biocompatible tests", Proc. SPIE 2629, Biomedical Optoelectronics in Clinical Chemistry and Biotechnology, (8 January 1996); https://doi.org/10.1117/12.229515