1 May 1991 In-line power meter for use during laser angioplasty
Roy E. Smith, Peter Milnes, David H. Edwards, David C. Mitchell, Richard F. M. Wood M.D.
Author Affiliations +
Proceedings Volume 1425, Diagnostic and Therapeutic Cardiovascular Interventions; (1991) https://doi.org/10.1117/12.44023
Event: Optics, Electro-Optics, and Laser Applications in Science and Engineering, 1991, Los Angeles, CA, United States
Abstract
Recanalization of occluded limb arteries can be accomplished using a pulsed dye laser. Either ball-tipped 600 micrometers fused quartz optical fibers or over-the-wire multifiber catheters are used to deliver laser energy. The alignment of the device is adjusted to achieve maximal transmitted power. To monitor power output during surgery the authors have developed an in- line powermeter (ILP). On leaving the laser the ball-tipped optical fiber is magnetically clamped in a V-groove. Radial light emission is converted to an electrical signal which is integrated to give an analogue output proportional to power. The reading is adjusted to be concordant with that from the bolometer. Over the range 20 to 200 mJ per pulse the linearity was better than 2.5% of full scale. The coefficient of variation of the ILP output following repeated placement of the same aligned fiber in the V-groove was less than 7%. Flexing the fiber through 90 degree(s) 10 cm from the V-groove caused the registered power to fall by up to 7%. In the case of the multifiber catheter a modified clamping arrangement was used. Linearity for a 7 Fr catheter comprising 15 fibers 200 micrometers in diameter was better than 5% of full scale; the coefficient of variation for repeated alignment of a catheter was 14%. The catheters do not have a circular section, which accounts for this large variation. Flexing the catheters had no consistent effect on registered power, but changes of up to +/- 10% could be obtained by extreme bending of the catheter. The output of the ILP does not appear to be affected by the nature of the target. Changes in output power and/or delivery device alignment can be detected and corrected during laser angioplasty. Accurate control of power delivered without exposing the tip of the fiber reduces the risk of injury from inadvertent laser discharge and aids optimal ablation of atheroma. The ILP ensures that effective power is maintained throughout the procedure.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Roy E. Smith, Peter Milnes, David H. Edwards, David C. Mitchell, and Richard F. M. Wood M.D. "In-line power meter for use during laser angioplasty", Proc. SPIE 1425, Diagnostic and Therapeutic Cardiovascular Interventions, (1 May 1991); https://doi.org/10.1117/12.44023
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical fibers

Francium

Power meters

Laser therapeutics

Diagnostics and therapeutics

Fiber lasers

Laser energy

Back to Top