Paper
29 May 2024 Evaluating an image restoration pipeline for digital mammography across varied radiation exposures and microcalcification sizes using model observer analysis
Author Affiliations +
Proceedings Volume 13174, 17th International Workshop on Breast Imaging (IWBI 2024); 1317412 (2024) https://doi.org/10.1117/12.3026930
Event: 17th International Workshop on Breast Imaging (IWBI 2024), 2024, Chicago, IL, United States
Abstract
In this study, we assess the impact of an image restoration pipeline, designed for digital mammography, on the detectability of microcalcifications of different sizes across varied radiation exposures. The restoration pipeline first removes the noise of the image considering a Poisson-Gaussian noise model that incorporates quantum and electronic noise. Then, it appropriately merges the noisy and denoised images to achieve a signal-to-noise ratio (SNR) comparable to an image obtained at a higher radiation dose. We created a database of mammographic images acquired at radiation doses between 50% and 200% of the automatic exposure control (AEC) using a physical anthropomorphic breast phantom. Clustered microcalcifications with diameters ranging from 190𝜇m to 390𝜇m were artificially inserted into the phantom images in regions with increased density. The Channelized Hotelling Observer (CHO) was employed as the model observer (MO) to evaluate the detectability of microcalcifications. A pilot study was conducted to adjust the percentage of correct detection to approximately 75% for microcalcifications with a diameter of 270𝜇m at the AEC dose. We applied the restoration pipeline to the image dataset and calculated the percentage of correctly detected signals (PC) using the MO in a four-alternative forced choice (4-AFC) study. The results indicated a PC enhancement of up to 10% when applying restoration to simulate acquisitions with twice the AEC dose. Additionally, for images acquired with radiation doses below the AEC, our results demonstrated a potential dose reduction of up to 22.4% without compromising microcalcification detectability. The detection of microcalcifications with a diameter of 390𝜇m remained unaffected by variations in radiation dose.
(2024) Published by SPIE. Downloading of the abstract is permitted for personal use only.
Renann F. Brandão, Lucas E. Soares, Lucas R. Borges, Predrag R. Bakic, Anders Tingberg, and Marcelo A. C. Vieira "Evaluating an image restoration pipeline for digital mammography across varied radiation exposures and microcalcification sizes using model observer analysis", Proc. SPIE 13174, 17th International Workshop on Breast Imaging (IWBI 2024), 1317412 (29 May 2024); https://doi.org/10.1117/12.3026930
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image restoration

Signal detection

Image quality

Mammography

Signal to noise ratio

Digital mammography

Quantum noise

Back to Top