Abstract
We report on vein imaging simulation studies using Zemax OpticStudio simulation software. These simulations are done using a 9-layer skin model. All the parameters save the thickness are wavelength dependent, and the simulation was considered at three different wavelengths – 650nm, 780nm and 850nm. For the vein in a given layer and at a given incident wavelength, the source-lens-detector setup was placed at various angles. Simulation results show the angle-dependent penetration of near-infrared (NIR) light into the skin and provide design inputs on the optimum wavelength and angle for vein illumination.
© (2023) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Satya Prasanna Mallick, Parishkrith A., Haritha V., V. Sai Muthukumar, R. Gopal, and V. Sharma "Wavelength and illumination angle dependent studies for vein imaging using OpticStudio", Proc. SPIE 12628, Diffuse Optical Spectroscopy and Imaging IX, 126282A (9 August 2023); https://doi.org/10.1117/12.2670866