17 February 2022 Erratum: Improved accuracy of cerebral blood flow quantification in the presence of systemic physiology cross-talk using multi-layer Monte Carlo modeling
Author Affiliations +
Abstract

The erratum corrects an error in Equation 1 of the published article.

This article [Neurophotonics 8(1), 015001 (2021) doi: https://doi.org/10.1117/1.NPh.8.1.015001] was originally published on 11 July 2021 with an error in Equation 1. The equation should have had negatives in both of the exponent expressions [i.e., exp(−Kr1) and exp(−Kr2)].

The negatives were added to the exponent expressions to correct the equation and the article was republished on 4 February 2022.

© The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
Melissa M. Wu, Suk-Tak Chan, Dibbyan Mazumder, Davide Tamborini, Kimberly A. Stephens, Bin Deng, Parya Farzam, Joyce Y. Chu, Maria Angela A. Franceschini, Jason Z. Qu, and Stefan A. Carp "Erratum: Improved accuracy of cerebral blood flow quantification in the presence of systemic physiology cross-talk using multi-layer Monte Carlo modeling," Neurophotonics 9(1), 019801 (17 February 2022). https://doi.org/10.1117/1.NPh.9.1.019801