Paper
22 May 2007 Glucose oxidase characterization for the fabrication of hybrid microelectronic devices
Manuela Fichera, Sebania Libertino, Venera Aiello, Antonino Scandurra, Fulvia Sinatra, Marcella Renis, Salvatore Lombardo
Author Affiliations +
Proceedings Volume 6592, Bioengineered and Bioinspired Systems III; 65920T (2007) https://doi.org/10.1117/12.721862
Event: Microtechnologies for the New Millennium, 2007, Maspalomas, Gran Canaria, Spain
Abstract
We studied the enzyme glucose oxidase (GOx) immobilization on silicon oxide surfaces. In particular, we optimized the immobilization protocol and verified that it fulfills both requirements of enzyme preservation (measured by enzymatic activity) and VLSI compatibility. The immobilization consists of four steps: oxide activation, silanization, linker molecule deposition and GOx immobilization. It is crucial to form an uniform linker layer on the sample surface in order to maximize the sites available for enzyme bonding and achieving the best enzyme deposition. In this study, utilizing glutaraldehyde as bifunctional reagent, we monitored its uniformity on the surface through X-ray Photoelectron Spectroscopy (XPS). Once optimized, the same protocol was used to anchor the enzyme in a porous silicon dioxide matrix. Gold labeled GOx molecules were monitored by electron diffraction X-ray (EDX) measurements coupled with scanning electron microscopy (SEM). The enzymatic activity was also monitored to confirm the goodness of the proposed immobilization method. Finally, the electrical characterization of MOS capacitors, showing a shift of about 1 V in the flat band voltage, demonstrated the possibility to use this approach for electrical detection.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Manuela Fichera, Sebania Libertino, Venera Aiello, Antonino Scandurra, Fulvia Sinatra, Marcella Renis, and Salvatore Lombardo "Glucose oxidase characterization for the fabrication of hybrid microelectronic devices", Proc. SPIE 6592, Bioengineered and Bioinspired Systems III, 65920T (22 May 2007); https://doi.org/10.1117/12.721862
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Glucose

Silicon

Gold

Biosensors

Scanning electron microscopy

Picosecond phenomena

Magnesium

RELATED CONTENT


Back to Top