Paper
17 March 2005 Quasi-monochromatic cerium flash angiography
Eiichi Sato, Rudolf Germer, Etsuro Tanaka, Hidezo Mori, Toshiaki Kawai, Toshio Ichimaru, Shigehiro Sato, Hidenori Ojima, Kazuyoshi Takayama, Hideaki Ido
Author Affiliations +
Proceedings Volume 5580, 26th International Congress on High-Speed Photography and Photonics; (2005) https://doi.org/10.1117/12.567575
Event: 26th International Congress on High-Speed Photography and Photonics, 2004, Alexandria, Virginia, United States
Abstract
The cerium target plasma flash x-ray generator is useful in order to perform high-speed enhanced K-edge angiography using cone beams because K-series characteristic x rays from the cerium target are absorbed effectively by iodine-based contrast mediums. In the flash x-ray generator, a 150 nF condenser is charged up to 80 kV by a power supply, and flash x rays are produced by the discharging. The x-ray tube is a demountable diode, and the turbomolecular pump evacuates air from the tube with a pressure of approximately 1 mPa. Since the electric circuit of the high-voltage pulse generator employs a cable transmission line, the high-voltage pulse generator produces twice the potential of the condenser charging voltage. At a charging voltage of 80 kV, the estimated maximum tube voltage and current were approximately 160 kV and 40 kA, respectively. When the charging voltage was increased, the K-series characteristic x-ray intensities of cerium increased. The K lines were clean and intense, and hardly any bremsstrahlung rays were detected at all. The x-ray pulse widths were approximately 100 ns, and the time-integrated x-ray intensity had a value of approximately 10 μC/kg at 1.0 m from the x-ray source with a charging voltage of 80 kV. In the angiography, we employed a film-less computed radiography (CR) system and iodine-based microspheres.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eiichi Sato, Rudolf Germer, Etsuro Tanaka, Hidezo Mori, Toshiaki Kawai, Toshio Ichimaru, Shigehiro Sato, Hidenori Ojima, Kazuyoshi Takayama, and Hideaki Ido "Quasi-monochromatic cerium flash angiography", Proc. SPIE 5580, 26th International Congress on High-Speed Photography and Photonics, (17 March 2005); https://doi.org/10.1117/12.567575
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Cerium

Angiography

Iodine

Plasma

X-ray sources

Medical research

RELATED CONTENT


Back to Top